Evaluation Of Behavior Of Fault Current Limiters On Power Quality Of Distribution Networks With Presence Of Disturbed Generation - Núm. Special Issue, Febrero 2017 - Quid. Investigación, Ciencia y Tecnología - Libros y Revistas - VLEX 697135529

Evaluation Of Behavior Of Fault Current Limiters On Power Quality Of Distribution Networks With Presence Of Disturbed Generation

AutorNader Rezai - Amir Ahmarinejad
CargoIslamic Azad University - Islamic Azad University
Páginas1044-1050
QUID 2017, pp. 1044-1050, Special Issue N°1- ISS N: 1692-343X, Medellín-Colombia
EVALUATION OF BEHAVIOR OF FAULT CURRENT LIMITERS ON POWER QUALITY OF
DISTRIBUTION NETWORKS WITH PRESENCE OF DISTURBED GENERAT ION
(Recibido el 17-05-2017. Aprobado el 11-08-2017)
Nader Rezai
Islamic Azad University,
Gradua te Student, Department of Electrical
Engineering, Yadegar-e-Imam Khomeini (RAH) Shahr-
e-Rey Branch,Tehra n, Iran
Amir Ahmarinejad
Islamic Azad University
Assistant Professor, Depa rtment of Electrica l
Engineering, Yadegar-e-Imam Khomeini (RAH) Shahr-
e-Rey Branch,Tehra n, Iran.
Resumen: Hoy en día, los problemas de calidad energética son uno de los problemas más importantes e n las redes de
distribución, que han atraído en gran medida la atención de investigadores e ingenieros eléctricos. La principal y última
razón para prestar atención a la calidad del poder en el sistema de distribución puede ser cuestiones económicas. Los
estudios de calidad de la energía indican que entre el 80% y el 90% de las qu ejas de los suscriptores de la compañía de
energía se deben a la falta de potencia debido a la falta d e voltaje, y la principal razón de la falta de voltaje son las fallas
de cortocircuito. Por lo tanto, el limitador de corriente de falla es una solución conveniente y económica para resolver
este prob lema. En este trabajo se utiliza FCL en el sistema de distribución y cuando se produce un fallo en la bar ra
colectora 5, los cambios de voltaje y corriente se observan utilizando un limitador y sin utilizarlo.
Palabras clave: Limitador de corriente de falla, Mejora de la calidad de la alimentación, Sistema IEEE 9 -Busbar
Abstract: Today, the power quality problems are one of the most important problems in distribution networks, which
have largely attracted the attention of researc hers and electrical engineers. The main and final reason for paying
attention to the quality of power in the distribution system can be economic issues. Power quality studies indicate that
between 80% and 90% of subscriber complaints from the power company are due to the lack of power due to the lack
of voltage, and the main reason for the lack of volta ge is short circuit faults. Therefore, the fault current limiter is a
convenient and economical solution to solve this problem. In this paper, FCL is used in the distrib ution syste m, and
when the fault occurs in the busbar 5, voltage and current changes are observed using a limiter and without usin g it.
Keywords: Fault Current Limiter, Improving the Power Quality, IEEE 9 -Busbar System